4010-01-152-7150 WIRE ROPE ASSEMBLY,SINGLE LEG Index 5935-01-152-7152 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5915-01-152-7151

Federal Supply Class:
5915

National Item Identification Number:
011527151

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
64-9394-0104423TELONIC BERKELEY, INC.
TLP170-4XX104423TELONIC BERKELEY, INC.


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION20.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY LENGTH5.000 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND 40.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.875 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.00 HERTZ BLANK AND 170.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATION50-008-3196
INPUT TERMINAL MANUFACTURER CODE98291
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATION50-008-3196
OUTPUT TERMINAL MANUFACTURER CODE98291
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL WIDTH0.656 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE-20.0 TO 50.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION85.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESWIRE LEADS WITH PLUG CONNECTORS
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ BLANK AND 170.00 MEGAHERTZ BLANK AND 245.00 MEGAHERTZ BLANK AND 490.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION130.0 MEGAHERTZ BLANK AND 170.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED