5935-01-149-9395 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5930-01-149-9397 SWITCH,PRESSURE

National Stock Number:
5915-01-149-9396

Federal Supply Class:
5915

National Item Identification Number:
011499396

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
64-9402-0104423TELONIC BERKELEY, INC.
TSF160.5-1.6-6XX104423TELONIC BERKELEY, INC.


Techincal Specification:
BODY LENGTH7.000 INCHES NOMINAL
BODY WIDTH1.875 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.120 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH7.375 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION159.70 MEGAHERTZ BLANK AND 161.30 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATION50-048-0000
INPUT TERMINAL MANUFACTURER CODE98291
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-0.0 TO 50.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATION50-048-0000
OUTPUT TERMINAL MANUFACTURER CODE98291
OVERALL HEIGHT1.312 INCHES NOMINAL
OVERALL LENGTH7.750 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 SLOT LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION160.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION159.9 MEGAHERTZ BLANK AND 161.1 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION157.90 MEGAHERTZ BLANK AND 159.70 MEGAHERTZ BLANK AND 161.30 MEGAHERTZ BLANK AND 163.70 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES