5915-01-145-8738 FILTER,RADIO FREQUENCY INTERFERE Index 5915-01-145-8740 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-145-8739

Federal Supply Class:
5915

National Item Identification Number:
011458739

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
9B875-113058SORA POWER INC.
C70-5D54841CAPCON INTERNATIONAL INC
RF1210113619EMS DEVELOPMENT CORPORATION
SM-A-838309-280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY LENGTH22.000 INCHES NOMINAL
BODY WIDTH4.620 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH3.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH23.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT5.250 INCHES NOMINAL
OVERALL LENGTH25.000 INCHES NOMINAL
MAXIMUM VOLTAGE DROP PER FUNCTION2.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY4 SLOT LOCATION NOT OTHERWISE SPECIFIED
MOUNTING SLOT WIDTH0.375 INCHES NOMINAL
OPERATING CURRENT RATING PER FUNCTION IN AMPS70.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-29.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT35.000 POUNDS NOMINAL


Click here to Register for Free 30-day Trial