5930-01-137-8749 SWITCH SUBASSEMBLY Index 5895-01-137-8751 MIXER STAGE,FREQUENCY

National Stock Number:
5915-01-137-8750

Federal Supply Class:
5915

National Item Identification Number:
011378750

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2139004G00119564CRSI INC DELAWARE DIV GENERAL DYNAMICS SATCOM TECHNOLOGIES INC.
2139004G00121441MOOG AIRCRAFT GROUP DBA S R ENGINEERING
BP03/1080-432-5AA0AEV7WILLIAM WHEELER
2139004G00128527L3HARRIS TECHNOLOGIES, INC.
BPF-T-102-431-1098856216TELEDYNE WIRELESS, LLC
SF-1080-432-6AA56216TELEDYNE WIRELESS, LLC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION60.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY MATERIALALUMINUM
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION864.00 MEGAHERTZ BLANK AND 1.296 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.6 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH4.100 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-40.0 TO 105.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.08 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+4.0 TO 50.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION886.0 MEGAHERTZ BLANK AND 1.274 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION215.00 MEGAHERTZ BLANK AND 864.00 MEGAHERTZ BLANK AND 1.296 GIGAHERTZ BLANK AND 1.685 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES