3120-01-135-7333 BEARING SET,SLEEVE Index 5930-01-135-7335 SWITCH,PRESSURE

National Stock Number:
5915-01-135-7334

Federal Supply Class:
5915

National Item Identification Number:
011357334

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
1422-10B59901MTK ELECTRONICS INC
RF02925-10B13619EMS DEVELOPMENT CORPORATION
RF2925-10B13619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY HEIGHT3.187 INCHES MINIMUM AND 3.249 INCHES MAXIMUM
BODY LENGTH3.187 INCHES MINIMUM AND 3.313 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.032 INCHES MINIMUM AND 2.094 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.484 INCHES MINIMUM AND 2.516 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT FIRST FUNCTION
FEATURES PROVIDEDMOUNTING BRACKET AND NUT
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS40.0 AND 80.0
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.01 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH8.440 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE230.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 SLOT FIRST FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) SECOND FUNCTION
MOUNTING SLOT WIDTH0.281 INCHES NOMINAL
NOMINAL THREAD SIZE0.190 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES