| BODY HEIGHT | 1.600 INCHES NOMINAL |
| BODY LENGTH | 2.190 INCHES NOMINAL |
| BODY MATERIAL | METAL |
| BODY WIDTH | 2.060 INCHES NOMINAL |
| CRITICALITY CODE JUSTIFICATION | SPCL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 25 WIRE LEAD OUTPUT SECOND FUNCTION |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| LOAD IMPEDANCE PER FUNCTION | 2.4 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 2.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 2.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 3.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 3.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 3.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.27 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.27 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| OPERATING TEMP RANGE | -80.0 TO 180.0 FAHRENHEIT |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 30.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 30.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 30.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 30.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 30.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 2.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 2.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 2.4 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 3.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 3.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 3.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| SPECIAL FEATURES | 13 FUNCTIONS |
| SPECIAL TEST FEATURES | WEAPONS SYSTEMS BRU-32/A(61A-W097) |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |