3120-01-126-4788 BUSHING,SLEEVE Index 5930-01-126-4792 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-126-4791

Federal Supply Class:
5915

National Item Identification Number:
011264791

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
293-1331-01000136MICROSEMI CORP. - HIGH PERFORMANCE TIMING
293-1331-01013499ROCKWELL COLLINS, INC.
293-1331-01082567CTS REEVES FREQUENCY PRODUCTS


Techincal Specification:
BODY HEIGHT0.800 INCHES MAXIMUM
BODY MATERIALMETAL
BODY LENGTH4.000 INCHES MAXIMUM
BODY WIDTH2.750 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.150 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.400 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION450.25 KILOHERTZ BLANK AND 453.10 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION2.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.300 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION2.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION450.4 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION449.00 KILOHERTZ BLANK AND 450.25 KILOHERTZ BLANK AND 453.10 KILOHERTZ BLANK AND 453.55 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial