Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2939247-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BODY HEIGHT2.250 INCHES NOMINAL
BODY LENGTH9.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH7.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH6.630 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH9.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OVERALL LENGTH10.800 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE600.0 VOLTS AT ALTITUDE
MAXIMUM TEMP RISE15.0 CELSIUS
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY12 THREADED STUD(S) FIRST FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY6 SLOT SECOND FUNCTION
MOUNTING SLOT WIDTH0.280 INCHES NOMINAL
NOMINAL THREAD SIZE0.190 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 3RD RADIO INTERFERENCE AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 3RD RADIO INTERFERENCE THIRD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES