5915-01-121-9444 FILTER,BANDPASS Index 5930-01-121-9446 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-121-9445

Federal Supply Class:
5915

National Item Identification Number:
011219445

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
003455-27212763DYNALEC CORPORATION
3448 ITEM 18497536WING CORP
A03DMS3C1100656AEROVOX CORP.
3W13A05245TE CONNECTIVITY CORPORATION
3W1A05245TE CONNECTIVITY CORPORATION
3455-27297536WING CORP
USE003455-27212763DYNALEC CORPORATION


Techincal Specification:
BODY HEIGHT1.750 INCHES NOMINAL
BODY LENGTH2.750 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.130 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.380 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
OVERALL LENGTH3.100 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCAPACITANCE-INDUCTANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCAPACITANCE-INDUCTANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
UNTHREADED MOUNTING HOLE DIAMETER0.156 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES