4820-01-119-5125 VALVE,BALL Index 5307-01-119-5130 STANDOFF,THREADED,SPACING

National Stock Number:
5915-01-119-5126

Federal Supply Class:
5915

National Item Identification Number:
011195126

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1040-003326192CUSHMAN ELECTRONICS INC


Techincal Specification:
BODY HEIGHT0.875 INCHES MAXIMUM
BODY MATERIALMETAL
BODY LENGTH4.016 INCHES NOMINAL
BODY WIDTH3.172 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.565 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.400 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION79.96 KILOHERTZ BLANK AND 80.04 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION80.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION79.84 KILOHERTZ BLANK AND 79.96 KILOHERTZ BLANK AND 80.04 KILOHERTZ BLANK AND 80.16 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE