5935-01-115-4241 CONNECTOR BODY,PLUG,ELECTRICAL Index 5930-01-115-4243 SWITCH,PRESSURE

National Stock Number:
5915-01-115-4242

Federal Supply Class:
5915

National Item Identification Number:
011154242

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
CMC246-803093-00090073CMC ELECTRONICS INC
F-1487/U80058JOINT ELECTRONICS TYPE DESIGNATION SYSTEM
TTF-500-5-3EE04423TELONIC BERKELEY, INC.


Techincal Specification:
BODY HEIGHT5.094 INCHES NOMINAL
BODY MATERIALMETAL
BODY LENGTH5.438 INCHES NOMINAL
BODY WIDTH2.812 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION375.00 MEGAHERTZ BLANK AND 750.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.8 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT6.219 INCHES NOMINAL
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION512.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION375.0 MEGAHERTZ BLANK AND 750.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED