5915-01-107-8595 FILTER,BAND SUPPRESSION Index 5920-01-107-8597 FUSE,CARTRIDGE

National Stock Number:
5915-01-107-8596

Federal Supply Class:
5915

National Item Identification Number:
011078596

Description:
FILTER,BAND SUPPRESSION

Detail:
AN ITEM DESIGNED TO SUPPRESS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO PASS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
20-0584-0611402HISONIC, LLC
673-0050-06095105ROCKWELL COLLINS, INC.


Techincal Specification:
BODY HEIGHT4.250 INCHES NOMINAL
BODY LENGTH10.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.190 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH9.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION28.60 KILOHERTZ BLANK AND 29.40 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.25 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-20.0 TO 50.0 CELSIUS
OVERALL LENGTH10.800 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.164 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION29.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION28.20 KILOHERTZ BLANK AND 28.60 KILOHERTZ BLANK AND 29.40 KILOHERTZ BLANK AND 29.80 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES