Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
RF0075713619EMS DEVELOPMENT CORPORATION
RF75713619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY LENGTH4.250 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER1.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH5.190 INCHES NOMINAL
MAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC BLANK AND 6.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.438 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC BLANK AND 600.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES