5915-01-105-1651 FILTER,RADIO FREQUENCY INTERFERE Index 5915-01-105-1653 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-105-1652

Federal Supply Class:
5915

National Item Identification Number:
011051652

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
654VE4846-381755LOCKHEED MARTIN CORPORATION
6B340-1090/20-0/050140K&L MICROWAVE LLC
BD1090-20-6SS67195SPECTRUM FSY MICROWAVE, INC.


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION40.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.750 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS70.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.08 GIGAHERTZ BLANK AND 1.10 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATIONSMA-JACK
INPUT TERMINAL MANUFACTURER CODE81755
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA-JACK
OUTPUT TERMINAL MANUFACTURER CODE81755
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH5.200 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.09 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.08 GIGAHERTZ BLANK AND 1.1 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION20.00 MEGAHERTZ BLANK AND 1.08 GIGAHERTZ BLANK AND 1.10 GIGAHERTZ BLANK AND 2.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES