5915-01-104-3978 FILTER,BAND PASS Index 5915-01-104-3980 FILTER,BAND PASS

National Stock Number:
5915-01-104-3979

Federal Supply Class:
5915

National Item Identification Number:
011043979

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
34-1216728-607397GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
F1002950310RYT INDUSTRIES INC
FC549460583STELLANT SYSTEMS INC


Techincal Specification:
BODY LENGTH1.400 INCHES NOMINAL
BODY WIDTH0.600 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.400 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION11.90 GIGAHERTZ BLANK AND 12.10 GIGAHERTZ BLANK
INCLOSURE TYPEENCASED
INPUT TERMINAL MANUFACTURER CODE07397
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.75 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S)
NOMINAL THREAD SIZE0.086 INCHES
OPERATING TEMP RANGE+0.0 TO 85.0 CELSIUS
OUTPUT TERMINAL MANUFACTURER CODE07397
OVERALL HEIGHT0.570 INCHES NOMINAL
OVERALL LENGTH1.900 INCHES NOMINAL
REFERENCE FREQUENCY PER FUNCTION12.0 GIGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION10.00 GIGAHERTZ BLANK AND 11.90 GIGAHERTZ BLANK AND 12.10 GIGAHERTZ BLANK AND 14.00 GIGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 500.0
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION11.9 GIGAHERTZ BLANK AND 12.1 GIGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK


Click here to Register for Free 30-day Trial