4820-01-100-7060 VALVE,SAFETY RELIEF Index 5915-01-100-7062 FILTER,BAND PASS-BAND SUPPRESSIO

National Stock Number:
5915-01-100-7061

Federal Supply Class:
5915

National Item Identification Number:
011007061

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2700-0001-0042161CXR LARUS CORPORATION DIV CXR TELCOM
5004-610G613050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
5004-610G6E13050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
6EF126364COMPONENTS CORP


Techincal Specification:
BODY HEIGHT1.550 INCHES MAXIMUM
BODY LENGTH1.175 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.188 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.575 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS6.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS6.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OVERALL HEIGHT1.970 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 FLANGE FIRST FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S) SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
UNTHREADED MOUNTING HOLE DIAMETER0.140 INCHES NOMINAL
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE