5915-01-098-9267 FILTER,BAND PASS Index 5930-01-098-9269 SWITCH,PRESSURE

National Stock Number:
5915-01-098-9268

Federal Supply Class:
5915

National Item Identification Number:
010989268

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2938662-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
TBP240-11-5SS104423TELONIC BERKELEY, INC.


Techincal Specification:
BODY OUTSIDE DIAMETER0.530 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM SINGLE BAND PASS SECOND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM SINGLE BAND PASS THIRD FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS70.0 MINIMUM SINGLE BAND PASS FOURTH FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS80.0 MINIMUM SINGLE BAND PASS FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 CONNECTOR, PLUG INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED
FREQUENCY BAND WIDTH PER FUNCTION4.50 MEGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH6.000 INCHES MINIMUM AND 6.500 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 CONNECTOR LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION240.0 MEGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION3.5 MEGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION269.00 MEGAHERTZ SINGLE BAND PASS AND 286.00 MEGAHERTZ SINGLE BAND PASS THIRD FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION183.50 MEGAHERTZ SINGLE BAND PASS AND 210.50 MEGAHERTZ SINGLE BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.00 MEGAHERTZ SINGLE BAND PASS AND 183.50 MEGAHERTZ SINGLE BAND PASS FIRST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION286.00 MEGAHERTZ SINGLE BAND PASS AND 1000.00 MEGAHERTZ SINGLE BAND PASS FOURTH FUNCTION
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial