5915-01-096-6262 FILTER,BAND SUPPRESSION Index 5915-01-096-6264 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-096-6263

Federal Supply Class:
5915

National Item Identification Number:
010966263

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
16402735351GE AVIATION SYSTEMS LLC
164027-0135351GE AVIATION SYSTEMS LLC
A333923939THE CAPTOR CORPORATION


Techincal Specification:
BODY HEIGHT2.600 INCHES MAXIMUM
BODY LENGTH2.700 INCHES MAXIMUM
BODY WIDTH1.300 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.125 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY5 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT-GROUND FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONMS27471Y1D35P
INPUT TERMINAL MANUFACTURER CODE35351
OVERALL HEIGHT3.040 INCHES MAXIMUM
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 5TH RADIO INTERFERENCE FIFTH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.5 5TH RADIO INTERFERENCE FIFTH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING TEMP RANGE-54.0 TO 110.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
UNPACKAGED UNIT WEIGHT13.000 OUNCES NOMINAL


Click here to Register for Free 30-day Trial