6110-01-096-5516 AMPLIFIER,ELECTRONIC CONTROL Index 5865-01-096-5518 OSCILLATING GROUP

National Stock Number:
5915-01-096-5517

Federal Supply Class:
5915

National Item Identification Number:
010965517

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
2B3005-220-9AA56216TELEDYNE WIRELESS, LLC
713839-105869RAYTHEON COMPANY
TIF-3005-220-9SS104423TELONIC BERKELEY, INC.


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION20.0 WATTS 1ST BAND PASS FIRST FUNCTION
AVERAGE POWER RATING PER FUNCTION20.0 WATTS 2ND BAND PASS SECOND FUNCTION
BODY LENGTH5.748 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.620 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND PASS AND 60.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND PASS AND 60.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.895 MEGAHERTZ 2ND BAND PASS AND 3.115 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.895 MEGAHERTZ 1ST BAND PASS AND 3.115 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.3 1ST BAND PASS FIRST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.3 2ND BAND PASS SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND BAND PASS SECOND FUNCTION
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
OVERALL HEIGHT0.620 INCHES NOMINAL
OVERALL LENGTH6.500 INCHES NOMINAL
OVERALL WIDTH2.372 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 SLOT LOCATION NOT OTHERWISE SPECIFIED
MOUNTING SLOT WIDTH0.085 INCHES NOMINAL
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND PASS FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND BAND PASS SECOND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND PASS FIRST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION3.005 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION3.005 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: LB1.000
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.895 MEGAHERTZ 1ST BAND PASS AND 3.115 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.895 MEGAHERTZ 2ND BAND PASS AND 3.115 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 1ST BAND PASS FIRST FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 2ND BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.80 MEGAHERTZ 2ND BAND PASS AND 2.895 MEGAHERTZ 2ND BAND PASS AND 3.115 MEGAHERTZ 2ND BAND PASS AND 3.228 MEGAHERTZ 2ND BAND PASS SECOND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.80 MEGAHERTZ 1ST BAND PASS AND 2.895 MEGAHERTZ 1ST BAND PASS AND 3.115 MEGAHERTZ 1ST BAND PASS AND 3.228 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES