5915-01-093-6413 FILTER,BAND PASS Index 5930-01-093-6416 SWITCH,ROTARY

National Stock Number:
5915-01-093-6414

Federal Supply Class:
5915

National Item Identification Number:
010936414

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
5003-464832677COMSPACE CORPORATION
FN31753733FILTRONETICS, INC.
SC-D-69067804YE2VALCORE MANUFACTURING LLC
SC-D-6906780AM43LCR ELECTRONICS, INC
SC-D-69067820723VALCORE MANUFACTURING LLC
SC-D-69067880063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.865 INCHES MINIMUM AND 2.885 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.084 INCHES MINIMUM AND 1.104 INCHES MAXIMUM
BODY HEIGHT1.500 INCHES NOMINAL
BODY LENGTH3.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.710 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION600.0 OHMS 1ST RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION600.0 OHMS 3RD RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION600.0 OHMS 4TH RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION600.0 OHMS 2ND RADIO INTERFERENCE
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
INCLOSURE TYPEENCASED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 1ST RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 2ND RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ600.0 4TH RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ600.0 3RD RADIO INTERFERENCE
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM VOLTAGE DROP PER FUNCTION0.05 VOLTS AC 4TH RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION0.05 VOLTS AC 3RD RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 1ST RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION1.0 VOLTS AC 2ND RADIO INTERFERENCE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
NOMINAL THREAD SIZE0.190 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.04 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.04 4TH RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 2ND RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 1ST RADIO INTERFERENCE
OPERATING TEMP RANGE-55.0/+125.0 DEG CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION5.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION100.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION100.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL LENGTH4.125 INCHES NOMINAL
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS 2ND RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS 1ST RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS 3RD RADIO INTERFERENCE
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS 4TH RADIO INTERFERENCE
SPECIAL FEATURESFOUR FILTERED FUNCTIONS
VIBRATION RESISTANCE RANGE IN HERTZ+10.0/+500.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES