4820-01-093-0006 VALVE,BALL Index 5307-01-093-0009 STUD,SELF-LOCKING

National Stock Number:
5915-01-093-0007

Federal Supply Class:
5915

National Item Identification Number:
010930007

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
147355259KR ELECTRONICS INC
1473A55259KR ELECTRONICS INC
2117863-00112436BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
4206122558COAST/ADVANCED CHIP MAGNETICS, INC.
91757193NETCOM, INC


Techincal Specification:
BODY HEIGHT0.500 INCHES NOMINAL
BODY LENGTH2.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MAXIMUM BLANK AND 40.0 MINIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.700 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.800 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION300.00 KILOHERTZ BLANK AND 500.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD500.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT500.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.750 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION400.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION300.00 KILOHERTZ BLANK AND 500.00 KILOHERTZ BLANK AND 1.10 MEGAHERTZ BLANK AND 2.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE