5915-01-092-6418 FILTER,BAND PASS Index 5915-01-092-6420 FILTER,BAND PASS

National Stock Number:
5915-01-092-6419

Federal Supply Class:
5915

National Item Identification Number:
010926419

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
29597314482WATKINS-JOHNSON CO
5224-31BWN1CAES SYSTEMS LLC
WJ-5224-314482WATKINS-JOHNSON CO


Techincal Specification:
BODY HEIGHT1.401 INCHES NOMINAL
BODY LENGTH1.400 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.400 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 70.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.125 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.125 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION7.985 GIGAHERTZ BLANK AND 8.015 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONSMA-JACK-FEMALE
INPUT TERMINAL MANUFACTURER CODE14482
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS4.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-JACK-FEMALE
OUTPUT TERMINAL MANUFACTURER CODE14482
OVERALL LENGTH2.150 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION8.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ12.000
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION7.985 GIGAHERTZ BLANK AND 8.015 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.1 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION7.68 GIGAHERTZ BLANK AND 7.985 GIGAHERTZ BLANK AND 8.015 GIGAHERTZ BLANK AND 8.32 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial