2915-01-091-1867 VALVE,FUEL PRESSURIZING AND DRAIN Index 5915-01-091-1869 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-091-1868

Federal Supply Class:
5915

National Item Identification Number:
010911868

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
A-3187A23939THE CAPTOR CORPORATION
E-170223160LINDGREN RF ENCLOSURES INC ELMAG DIV
RF09083A13619EMS DEVELOPMENT CORPORATION
RF9083A13619EMS DEVELOPMENT CORPORATION
SM-C-93859213619EMS DEVELOPMENT CORPORATION
SM-C-93859256528FIL-COIL INTERNATIONAL LLC
SM-C-93859280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
SM-C-93859293790CORNELL-DUBILIER ELECTRONICS, INC.


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
BODY WIDTH2.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-30.0 TO 95.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION208.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH3.476 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION2.1 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY1 CONNECTOR LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES