5915-01-089-8803 FILTER,BAND PASS Index 5915-01-089-8805 FILTER,BAND PASS

National Stock Number:
5915-01-089-8804

Federal Supply Class:
5915

National Item Identification Number:
010898804

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
170211924022TELEDYNE DEFENSE ELECTRONICS, LLC
332524022TELEDYNE DEFENSE ELECTRONICS, LLC


Techincal Specification:
BODY HEIGHT1.080 INCHES NOMINAL
BODY LENGTH2.164 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.569 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.304 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.304 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.38 GIGAHERTZ BLANK AND 1.84 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONSMA-JACK
INPUT TERMINAL MANUFACTURER CODE24022
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-54.0 TO 110.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA-JACK
OUTPUT TERMINAL MANUFACTURER CODE24022
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY3 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.086 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.6 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.38 GIGAHERTZ BLANK AND 1.8 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.3 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION600.00 MEGAHERTZ BLANK AND 1.38 GIGAHERTZ BLANK AND 1.84 GIGAHERTZ BLANK AND 2.50 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial