5925-01-071-1845 CIRCUIT BREAKER Index 5930-01-071-1851 SWITCH,PRESSURE

National Stock Number:
5915-01-071-1850

Federal Supply Class:
5915

National Item Identification Number:
010711850

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
293-1282-02013499ROCKWELL COLLINS, INC.
2B37300136MICROSEMI CORP. - HIGH PERFORMANCE TIMING
2B373A00136MICROSEMI CORP. - HIGH PERFORMANCE TIMING


Techincal Specification:
BODY HEIGHT0.600 INCHES MAXIMUM
BODY LENGTH3.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.750 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS40.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.001249 MEGAHERTZ BLANK AND 2.001251 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS9.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION2.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 105.0 CELSIUS
OVERALL HEIGHT0.975 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION2.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION2.00125 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.001246 MEGAHERTZ BLANK AND 2.001249 MEGAHERTZ BLANK AND 2.001251 MEGAHERTZ BLANK AND 2.001252 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE