4820-01-058-4999 VALVE,BALL Index 5915-01-058-5001 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-058-5000

Federal Supply Class:
5915

National Item Identification Number:
010585000

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
24221L8V1MAGNETIKA INC
242253342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
J18157193NETCOM, INC
886C275P199971LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE SYSTEMS


Techincal Specification:
BODY HEIGHT0.520 INCHES MAXIMUM
BODY LENGTH2.020 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.020 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.700 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.700 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION27.50 MEGAHERTZ BLANK AND 32.50 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT0.800 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-25.0 TO 50.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION30.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION27.5 MEGAHERTZ BLANK AND 32.5 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE