4320-01-052-3418 SLEEVE,SHAFT,PUMP Index 5915-01-052-3421 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-052-3419

Federal Supply Class:
5915

National Item Identification Number:
010523419

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
666660583STELLANT SYSTEMS INC
F2617A53294NARDA MICROWAVE CORP THE WESTERN OPERATIONS
F2617A60583STELLANT SYSTEMS INC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION10.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY HEIGHT1.250 INCHES NOMINAL
BODY MATERIALMETAL
BODY LENGTH5.100 INCHES NOMINAL
BODY WIDTH1.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS50.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.050 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.900 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.00 GIGAHERTZ BLANK AND 4.00 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATIONSMA
INPUT TERMINAL MANUFACTURER CODE53294
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.8 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA
OUTPUT TERMINAL MANUFACTURER CODE53294
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH5.860 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION3.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.40 GIGAHERTZ BLANK AND 2.00 GIGAHERTZ BLANK AND 4.00 GIGAHERTZ BLANK AND 4.70 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.0 GIGAHERTZ BLANK AND 4.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.4 BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES