5915-01-050-0530 FILTER,RADIO FREQUENCY INTERFERE Index 6680-01-050-0532 TRANSMITTER,LIQUID QUANTITY

National Stock Number:
5915-01-050-0531

Federal Supply Class:
5915

National Item Identification Number:
010500531

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
0019379-010C9D4PERATON INC
RF0811413619EMS DEVELOPMENT CORPORATION
RF811413619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY MATERIALMETAL
BODY LENGTH4.000 INCHES NOMINAL
BODY OUTSIDE DIAMETER1.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH5.250 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE650.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION2.3 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNEF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.750 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION230.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 55.0
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES