3120-01-042-5153 BUSHING,SLEEVE Index 5915-01-042-5156 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-042-5155

Federal Supply Class:
5915

National Item Identification Number:
010425155

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
A-102-58723042TRILITHIC, INC.
A-102-5874S260L-3 COMMUNICATIONS MICRODYNE


Techincal Specification:
AVERAGE LIFE RATING IN HOURS87600.0
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS45.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.60 GIGAHERTZ BLANK AND 2.40 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONSMA
INPUT TERMINAL MANUFACTURER CODE21377
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+10.0 TO 70.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONSMA
OUTPUT TERMINAL MANUFACTURER CODE21377
OVERALL LENGTH4.875 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 CONNECTOR LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION2.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION1.6 GIGAHERTZ BLANK AND 2.4 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION500.00 MEGAHERTZ BLANK AND 1.60 GIGAHERTZ BLANK AND 2.40 GIGAHERTZ BLANK AND 3.50 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES