4820-01-040-7530 VALVE,BALL Index 5915-01-040-7532 FILTER,BAND PASS

National Stock Number:
5915-01-040-7531

Federal Supply Class:
5915

National Item Identification Number:
010407531

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
32-808852-107397GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS
32-808852-123042TRILITHIC, INC.
8BC375/300-KL23042TRILITHIC, INC.
6B120-375/300-0P/050140K&L MICROWAVE LLC
32-808852-194040BELL AND HOWELL CO ROCHESTER FILM DIV


Techincal Specification:
BODY OUTSIDE DIAMETER0.500 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION235.00 MEGAHERTZ BLANK AND 515.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INPUT TERMINAL IDENTIFICATIONSMA
INPUT TERMINAL MANUFACTURER CODE07397
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT TERMINAL IDENTIFICATIONSMA
OUTPUT TERMINAL MANUFACTURER CODE07397
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH4.950 INCHES MINIMUM AND 5.180 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 CONNECTOR LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+10.0 TO 85.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION375.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION125.00 MEGAHERTZ BLANK AND 235.00 MEGAHERTZ BLANK AND 515.00 MEGAHERTZ BLANK AND 680.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION235.0 MEGAHERTZ BLANK AND 515.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
TEST DATA DOCUMENT07397-32-808852 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)