| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| OVERALL HEIGHT | 2.000 INCHES NOMINAL |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| BODY HEIGHT | 1.750 INCHES NOMINAL |
| BODY LENGTH | 2.250 INCHES NOMINAL |
| BODY WIDTH | 0.860 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.500 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
| FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.15 AND 0.3 AND 0.5 AND 1.0 AND 10.0 AND 1000.0 |
| FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 52.0 AND 70.0 AND 90.0 AND 80.0 |
| INCLOSURE TYPE | ENCASED |
| INPUT TERMINAL IDENTIFICATION | 17258-S |
| INPUT TERMINAL MANUFACTURER CODE | 70903 |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |