| BODY HEIGHT | 1.406 INCHES NOMINAL |
| BODY LENGTH | 1.406 INCHES NOMINAL |
| BODY WIDTH | 1.406 INCHES NOMINAL |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 70.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 70.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.125 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.125 INCHES NOMINAL |
| FREQUENCY BAND WIDTH PER FUNCTION | 5.97 GIGAHERTZ 2ND BAND PASS AND 6.03 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 5.97 GIGAHERTZ 1ST BAND PASS AND 6.03 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| INCLOSURE TYPE | ENCASED |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 10.0 OHMS 1ST BAND PASS FIRST FUNCTION |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 10.0 OHMS 2ND BAND PASS SECOND FUNCTION |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.5 1ST BAND PASS FIRST FUNCTION |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.5 2ND BAND PASS SECOND FUNCTION |
| OVERALL LENGTH | 2.406 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| NOMINAL THREAD SIZE | 0.138 INCHES |
| OPERATING TEMP RANGE | +10.0 TO 65.0 CELSIUS |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 10.0 OHMS 1ST BAND PASS FIRST FUNCTION |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 10.0 OHMS 2ND BAND PASS SECOND FUNCTION |
| SPECIAL FEATURES | 2 @COIL TERMINALS AND 2 HEATER TERMINALS IN ADDITION TO INPUT AND OUTPUT TERMINALS |
| REFERENCE FREQUENCY PER FUNCTION | 6.0 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION |
| REFERENCE FREQUENCY PER FUNCTION | 6.0 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 5.68 GIGAHERTZ 1ST BAND PASS AND 5.97 GIGAHERTZ 1ST BAND PASS AND 6.03 GIGAHERTZ 1ST BAND PASS AND 6.32 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 5.68 GIGAHERTZ 2ND BAND PASS AND 5.97 GIGAHERTZ 2ND BAND PASS AND 6.03 GIGAHERTZ 2ND BAND PASS AND 6.32 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 2.1 2ND BAND PASS SECOND FUNCTION |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | 2.1 1ST BAND PASS FIRST FUNCTION |