3120-01-026-5909 BEARING,SLEEVE Index 5915-01-026-5912 FILTER,BAND PASS

National Stock Number:
5915-01-026-5911

Federal Supply Class:
5915

National Item Identification Number:
010265911

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
734460583STELLANT SYSTEMS INC
F2422A60583STELLANT SYSTEMS INC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION10.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
BODY LENGTH2.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH0.750 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS50.0 MINIMUM BLANK AND 5.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.800 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.550 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION9.985 GIGAHERTZ BLANK AND 10.015 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH2.760 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.086 INCHES
OPERATING TEMP RANGE+0.0 TO 65.0 CELSIUS
OVERALL HEIGHT0.600 INCHES NOMINAL
REFERENCE FREQUENCY PER FUNCTION10.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION9.750 GIGAHERTZ BLANK AND 9.985 GIGAHERTZ BLANK AND 10.015 GIGAHERTZ BLANK AND 10.250 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION9.985 GIGAHERTZ BLANK AND 10.015 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED


Click here to Register for Free 30-day Trial