5915-01-019-6573 FILTER,RADIO FREQUENCY INTERFERE Index 5915-01-019-6575 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-019-6574

Federal Supply Class:
5915

National Item Identification Number:
010196574

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
7930688-120234INTERNATIONAL BUSINESS MACHINES CORP
JN17-4722A56289SPRAGUE ELECTRIC CO WORLD HQS


Techincal Specification:
AVERAGE LIFE RATING IN HOURS5000.0
BODY HEIGHT1.780 INCHES MAXIMUM
BODY MATERIALMETAL
BODY LENGTH4.000 INCHES NOMINAL
BODY WIDTH3.810 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
INPUT TERMINAL IDENTIFICATIONMS27478Y16D8P
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
OUTPUT TERMINAL IDENTIFICATIONDEH9P202
OUTPUT TERMINAL MANUFACTURER CODE71468
OVERALL LENGTH5.750 INCHES NOMINAL
MAXIMUM TEMP RISE25.0 CELSIUS
OPERATING TEMP RANGE-54.0 TO 95.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNPACKAGED UNIT WEIGHT2.000 POUNDS NOMINAL