5915-01-019-5199 CAPACITOR-RESISTOR Index 5915-01-019-5201 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-019-5200

Federal Supply Class:
5915

National Item Identification Number:
010195200

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
9003-103-000412294MURATA ERIE NORTH AMERICA INC DIVOF MURATA ERIE
930450-1B82577RAYTHEON COMPANY
D-70150056PIEZOTHERMX CORPORATION
D49850056PIEZOTHERMX CORPORATION


Techincal Specification:
BODY LENGTH0.964 INCHES MAXIMUM
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER0.396 INCHES MINIMUM AND 0.416 INCHES MAXIMUM
BODY SURFACE TREATMENTTIN
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
INCLOSURE TYPEENCASED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS0.75 BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION450.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL LENGTH1.576 INCHES MAXIMUM
MAXIMUM TEMP RISE25.0 CELSIUS
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.250 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCAPACITANCE-INDUCTANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES