5915-01-014-6218 FILTER,BAND PASS Index 5915-01-014-6221 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-014-6219

Federal Supply Class:
5915

National Item Identification Number:
010146219

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
59742620418DRS SUSTAINMENT SYSTEMS, INC. USE CAGE CODE 98255 FOR CATALOGING


Techincal Specification:
BODY HEIGHT2.000 INCHES MAXIMUM
BODY LENGTH4.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.000 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 50.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.492 INCHES MINIMUM AND 1.508 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION6.240 KILOHERTZ SINGLE BAND PASS AND 6.3967 KILOHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OVERALL HEIGHT4.250 INCHES MINIMUM AND 4.350 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.111 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION6.31835 KILOHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ8.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.8303 KILOHERTZ BLANK AND 6.24 KILOHERTZ BLANK AND 6.3967 KILOHERTZ BLANK AND 6.4033 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE