4820-01-012-6253 VALVE,GLOBE Index 5915-01-012-6256 FILTER,BAND PASS

National Stock Number:
5915-01-012-6255

Federal Supply Class:
5915

National Item Identification Number:
010126255

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
222022558COAST/ADVANCED CHIP MAGNETICS, INC.
930448-1C82577RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT0.700 INCHES MAXIMUM
BODY LENGTH1.270 INCHES MINIMUM AND 1.330 INCHES MAXIMUM
BODY WIDTH0.720 INCHES MINIMUM AND 0.780 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.600 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.150 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE LEAD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 WIRE LEAD OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION4.78 KILOHERTZ BLANK AND 5.22 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION5.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.200 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE50.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-32.0 TO 52.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION5.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: GM40.000
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION4.125 KILOHERTZ BLANK AND 4.78 KILOHERTZ BLANK AND 5.22 KILOHERTZ BLANK AND 5.875 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial