5915-01-009-2008 FILTER,BAND PASS Index 5915-01-009-2010 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-009-2009

Federal Supply Class:
5915

National Item Identification Number:
010092009

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
926177-182577RAYTHEON COMPANY
L132201341MICROPHASE CORP


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT1.160 INCHES NOMINAL
BODY LENGTH6.130 INCHES NOMINAL
BODY WIDTH1.130 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS50.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.812 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH5.812 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION28.00 MEGAHERTZ BLANK AND 32.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONUG-1094/U
INPUT TERMINAL MANUFACTURER CODE80058
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OUTPUT TERMINAL IDENTIFICATIONUG-1094/U
OUTPUT TERMINAL MANUFACTURER CODE80058
OVERALL LENGTH7.060 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION30.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: OZ8.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION25.00 MEGAHERTZ BLANK AND 28.00 MEGAHERTZ BLANK AND 32.00 MEGAHERTZ BLANK AND 39.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES