5915-00-957-6806 FILTER,BAND PASS Index 1660-00-957-6808 BODY,VALVE

National Stock Number:
5915-00-957-6807

Federal Supply Class:
5915

National Item Identification Number:
009576807

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
2183370-111447L3 TECHNOLOGIES, INC.
2183370-149671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES
JN10-77456289SPRAGUE ELECTRIC CO WORLD HQS
NF20565-193790CORNELL-DUBILIER ELECTRONICS, INC.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS250.0
BODY LENGTH4.970 INCHES MINIMUM AND 5.030 INCHES MAXIMUM
BODY OUTSIDE DIAMETER1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 THREADED STUD OUTPUT SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
OVERALL LENGTH5.250 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION500.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 3RD RADIO INTERFERENCE THIRD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS10.0 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING TEMP RANGE-28.0 TO 85.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES