5915-00-951-8707 FILTER,BAND PASS Index 6240-00-951-8709 CLAMP

National Stock Number:
5915-00-951-8708

Federal Supply Class:
5915

National Item Identification Number:
009518708

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
3372420101955901DARE ELECTRONICS, INC.
37242-103040POWER CONTROL DEVICES, INC.
37242-109376OMNITEC DATA CORP SUB OF NYTRONICS INC
37242-142498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
37242-1REVK42498DAR ELECTRONICS INC DBA NATIONAL RADIO CO


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION100.0 KILOHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION99.70 KILOHERTZ BLANK AND
100.30 KILOHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
1 PIN OUTPUT 2ND FUNCTION
2 PIN GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
SOURCE IMPEDANCE RATING PER FUNCTION68.0 KILOHMS BLANK
LOAD IMPEDANCE PER FUNCTION68.0 KILOHMS BLANK
INPUT IMPEDANCE PER FUNCTION W/LOAD68.0 KILOHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT68.0 KILOHMS BLANK
OVERALL HEIGHT2.875 INCHES MAXIMUM
BODY LENGTH5.000 INCHES MAXIMUM
BODY HEIGHT2.500 INCHES MAXIMUM
BODY WIDTH1.500 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.437 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION99.13 KILOHERTZ BLANK AND
99.70 KILOHERTZ BLANK AND
100.30 KILOHERTZ BLANK AND
100.88 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND
1.0 MAXIMUM BLANK 1ST FUNCTION
OPERATING TEMP RANGE0.0 TO 70.0 DEG CELSIUS
BODY MATERIALMETAL


Click here to Register for Free 30-day Trial