5820-00-948-0220 DETECTOR Index 5930-00-948-0222 SWITCH,ROTARY

National Stock Number:
5915-00-948-0221

Federal Supply Class:
5915

National Item Identification Number:
009480221

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
39105-142498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
39105-1REVE42498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
S9658309376OMNITEC DATA CORP SUB OF NYTRONICS INC
A39105-142498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
A39105-1REVE42498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
603AB55342PILOT INDUSTRIES CORP


Techincal Specification:
BODY HEIGHT2.000 INCHES MAXIMUM
BODY LENGTH5.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.875 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 1ST BAND PASS AND 2.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 2ND BAND PASS AND 2.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.375 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 TAB, SOLDER LUG GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION100.40 KILOHERTZ 1ST BAND PASS AND 100.60 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION101.25 KILOHERTZ 2ND BAND PASS AND 101.75 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD68.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
INPUT IMPEDANCE PER FUNCTION W/LOAD68.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS SECOND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS FIRST FUNCTION
OPERATING TEMP RANGE+0.0 TO 70.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT68.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT68.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
OVERALL HEIGHT2.406 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION100.5 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
REFERENCE FREQUENCY PER FUNCTION101.5 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE