5961-00-945-4900 TRANSISTOR Index 5950-00-945-4903 REACTOR

National Stock Number:
5915-00-945-4902

Federal Supply Class:
5915

National Item Identification Number:
009454902

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
526-2864-01095105ROCKWELL COLLINS, INC.
FS9454-90256662FREQUENCY SELECTIVE NETWORKS, INC.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT3.188 INCHES MAXIMUM
BODY LENGTH2.425 INCHES MAXIMUM
BODY WIDTH1.875 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 1ST BAND PASS AND 3.0 NOMINAL 1ST BAND PASS FIRST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 2ND BAND PASS AND 3.0 NOMINAL 2ND BAND PASS SECOND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.195 INCHES MINIMUM AND 2.005 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY6 TURRET OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.755 HERTZ 2ND BAND PASS AND 1.875 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION875.00 HERTZ 1ST BAND PASS AND 995.00 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 2ND BAND PASS SECOND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 1ST BAND PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION20.0 KILOHMS 1ST BAND PASS FIRST FUNCTION
LOAD IMPEDANCE PER FUNCTION20.0 KILOHMS 2ND BAND PASS SECOND FUNCTION
OVERALL HEIGHT3.562 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE100.0 VOLTS AT ALTITUDE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE-20.0 TO 71.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION150.0 OHMS 1ST BAND PASS FIRST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION150.0 OHMS 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION1.995 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
REFERENCE FREQUENCY PER FUNCTION1.115 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.485 KILOHERTZ 2ND BAND PASS AND 1.755 KILOHERTZ 2ND BAND PASS AND 1.875 KILOHERTZ 2ND BAND PASS AND 2.785 KILOHERTZ 2ND BAND PASS SECOND FUNCTION
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION500.00 HERTZ 1ST BAND PASS AND 875.00 HERTZ 1ST BAND PASS AND 995.00 HERTZ 1ST BAND PASS AND 1.705 KILOHERTZ 1ST BAND PASS FIRST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial