| AVERAGE LIFE RATING IN HOURS | 10000.0 |
| BODY HEIGHT | 4.250 INCHES MAXIMUM |
| BODY LENGTH | 3.062 INCHES MAXIMUM |
| BODY MATERIAL | METAL |
| BODY WIDTH | 2.625 INCHES MAXIMUM |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 16.0 NOMINAL 1ST BAND PASS AND 1.0 NOMINAL 1ST BAND PASS FIRST FUNCTION |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 16.0 NOMINAL 2ND BAND PASS AND 1.0 NOMINAL 2ND BAND PASS SECOND FUNCTION |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.610 INCHES MINIMUM AND 2.640 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.281 INCHES MINIMUM AND 2.301 INCHES MAXIMUM |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TURRET GROUND THIRD FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TURRET OUTPUT SECOND FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TURRET INPUT FIRST FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 2.76 KILOHERTZ BLANK AND 2.84 KILOHERTZ BLANK AND 382.50 HERTZ BLANK AND 457.50 HERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| INCLOSURE TYPE | ENCASED |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 14.0 1ST BAND PASS FIRST FUNCTION |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 16.0 2ND BAND PASS SECOND FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 180.0 OHMS 1ST BAND PASS FIRST FUNCTION |
| LOAD IMPEDANCE PER FUNCTION | 180.0 OHMS 2ND BAND PASS SECOND FUNCTION |
| OVERALL HEIGHT | 4.690 INCHES MAXIMUM |
| MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 150.0 VOLTS AT SEA LEVEL |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| NOMINAL THREAD SIZE | 0.164 INCHES |
| OPERATING TEMP RANGE | -40.0 TO 80.0 CELSIUS |
| SOURCE IMPEDANCE RATING PER FUNCTION | 6.2 KILOHMS 1ST BAND PASS FIRST FUNCTION |
| SOURCE IMPEDANCE RATING PER FUNCTION | 6.2 KILOHMS 2ND BAND PASS SECOND FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST BAND PASS FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND BAND PASS SECOND FUNCTION |
| REFERENCE FREQUENCY PER FUNCTION | 2.805 KILOHERTZ 1ST BAND PASS FIRST FUNCTION |
| REFERENCE FREQUENCY PER FUNCTION | 425.0 HERTZ 2ND BAND PASS SECOND FUNCTION |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 2.55 KILOHERTZ 1ST BAND PASS AND 2.76 KILOHERTZ 1ST BAND PASS AND 2.84 KILOHERTZ 1ST BAND PASS AND 3.07 KILOHERTZ 1ST BAND PASS FIRST FUNCTION |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 220.00 HERTZ 2ND BAND PASS AND 382.50 HERTZ 2ND BAND PASS AND 457.50 HERTZ 2ND BAND PASS AND 740.00 HERTZ 2ND BAND PASS SECOND FUNCTION |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |