5915-00-927-9880 FILTER,HIGH PASS Index 5915-00-927-9883 FILTER,LOW PASS

National Stock Number:
5915-00-927-9881

Federal Supply Class:
5915

National Item Identification Number:
009279881

Description:
FILTER,HIGH PASS

Detail:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES ABOVE A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
2557886-310001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH2.060 INCHES NOMINAL
BODY WIDTH1.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS65.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK AND 0.5 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.600 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION2.61 KILOHERTZ BLANK AND 8.30 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD(S) FIRST FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0 TO 60.0 CELSIUS
OVERALL HEIGHT2.312 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION2.8 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSQUALITY CONTROLLED AND SELECTED
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.74 KILOHERTZ BLANK AND 2.61 KILOHERTZ BLANK AND 2.75 KILOHERTZ BLANK AND 8.30 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE