5945-00-927-9877 RELAY,ELECTROMAGNETIC Index 5915-00-927-9880 FILTER,HIGH PASS

National Stock Number:
5915-00-927-9879

Federal Supply Class:
5915

National Item Identification Number:
009279879

Description:
FILTER,HIGH PASS

Detail:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES ABOVE A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).


Manufacturer Information:
1069311L8V1MAGNETIKA INC
10693153342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
2557886-110001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
2557886-1REVE53711NAVAL SEA SYSTEMS COMMAND
HPF-101752-198330OECO, LLC


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT2.000 INCHES MAXIMUM
BODY LENGTH2.060 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.500 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS65.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.600 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION485.00 HERTZ BLANK AND 8.30 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT2.312 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0 TO 60.0 CELSIUS
SOURCE IMPEDANCE RATING PER FUNCTION1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION4.3925 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSQUALITY CONTROLLED AND SELECTED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 HERTZ BLANK AND 252.00 HERTZ BLANK AND 485.00 HERTZ BLANK AND 8.30 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE