| BODY LENGTH | 6.185 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 2.015 INCHES MAXIMUM |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD OUTPUT SECOND FUNCTION |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| OVERALL LENGTH | 8.435 INCHES MAXIMUM |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.4 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 400.0 VOLTS AC BLANK AND 1000.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| TEST DATA DOCUMENT | 10001-2469337-1 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |