5990-00-922-7317 RESOLVER,ELECTRICAL Index 5310-00-922-7321 WASHER,SPRING TENSION

National Stock Number:
5915-00-922-7318

Federal Supply Class:
5915

National Item Identification Number:
009227318

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
241-0476-0013499ROCKWELL COLLINS, INC.
X665-381815COMMUNICATION COIL, INC.


Techincal Specification:
BODY HEIGHT1.000 INCHES MAXIMUM
BODY LENGTH2.250 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH1.125 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.600 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.600 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION10.45 MEGAHERTZ BLANK AND 10.95 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN INPUT FIRST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD4.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT350.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.281 INCHES MAXIMUM
REFERENCE FREQUENCY PER FUNCTION10.7 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION10.10 MEGAHERTZ BLANK AND 10.45 MEGAHERTZ BLANK AND 10.95 MEGAHERTZ BLANK AND 11.30 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 500.0