5970-00-920-0485 INSULATOR,BUSHING Index 5915-00-920-0490 FILTER

National Stock Number:
5915-00-920-0486

Federal Supply Class:
5915

National Item Identification Number:
009200486

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
45G11-00-0225549LITTON SYSTEMS INC AMECOM DIV
45G11-00-0292755NORTHROP GRUMMAN SYSTEMS CORP
S9833909376OMNITEC DATA CORP SUB OF NYTRONICS INC


Techincal Specification:
BODY HEIGHT2.407 INCHES MINIMUM AND 2.469 INCHES MAXIMUM
BODY LENGTH2.531 INCHES MINIMUM AND 2.593 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS35.0 NOMINAL BLANK AND 3.0 NOMINAL BLANK FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND THIRD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT FIRST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.20 KILOHERTZ BLANK AND 4.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION2.6 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION800.00 HERTZ BLANK AND 1.20 KILOHERTZ BLANK AND 4.00 KILOHERTZ BLANK AND 6.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES


Click here to Register for Free 30-day Trial