3120-00-914-8766 BEARING,PLAIN,SELF-ALIGNING Index 5910-00-914-8771 CAPACITOR,FIXED,PLASTIC DIELECTRIC

National Stock Number:
5915-00-914-8768

Federal Supply Class:
5915

National Item Identification Number:
009148768

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1397307388TOROTEL, INC.
673-1057-00013499ROCKWELL COLLINS, INC.


Techincal Specification:
BODY HEIGHT0.563 INCHES MAXIMUM
BODY LENGTH4.500 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH4.063 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 24.0 MAXIMUM BLANK LOCATION NOT OTHERWISE SPECIFIED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH3.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.188 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 PIN GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.738 KILOHERTZ BLANK AND 1.832 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
LOAD IMPEDANCE PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
OVERALL HEIGHT0.657 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
SOURCE IMPEDANCE RATING PER FUNCTION600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
REFERENCE FREQUENCY PER FUNCTION1.785 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.615 KILOHERTZ BLANK AND 1.738 KILOHERTZ BLANK AND 1.832 KILOHERTZ BLANK AND 1.955 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE