5915-00-910-7124 FILTER,BAND PASS Index 5915-00-910-7126 FILTER,BAND PASS

National Stock Number:
5915-00-910-7125

Federal Supply Class:
5915

National Item Identification Number:
009107125

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
15350A93928DYCO ELECTRONICS INC
1536993928DYCO ELECTRONICS INC
FL010014304L3HARRIS TECHNOLOGIES, INC.
K05893928DYCO ELECTRONICS INC


Techincal Specification:
BODY HEIGHT1.065 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
BODY WIDTH1.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 NOMINAL BLANK AND 60.0 NOMINAL BLANK FIRST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET INPUT FIRST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET OUTPUT SECOND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TURRET GROUND THIRD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.535500 MEGAHERTZ BLANK AND 2.655500 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD10.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
OVERALL HEIGHT1.719 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE-40.0 TO 75.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION2.595500 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.395500 MEGAHERTZ BLANK AND 2.535500 MEGAHERTZ BLANK AND 2.655500 MEGAHERTZ BLANK AND 2.795500 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE